Parameters
PN# | PM-405-2-1-FC/APC | PM-488-2-1-FC/APC | PM-630-2-1-FC/APC | PM-780-2-1-FC/APC | PM-980-2-1-FC/APC |
Test wavelength | 405 nm | 488 nm | 630 nm | 780 nm | 980 nm |
Operating wavelength | 400 - 680 nm | 460 - 700 nm | 620 - 850 nm | 770 - 1100 nm | 970 - 1550 nm |
Cutoff wavelength | 380 ± 20 nm | 420 ± 30 nm | 570 ± 50 nm | 710 ± 60 nm | 920 ± 50 nm |
Fiber type | PM-S405-XP (Panda) | PM460-HP (Panda) | PM630-HP (Panda) | PM780-HP (Panda) | PM980-XP (Panda) |
Maximum insertion loss | 1.5 dB | 1.5 dB | 1.2 dB | 1.0 dB | 0.7 dB |
Minimum extinction ratio | 15 dB | 18 dB | 20 dB | 20 dB | 22 dB |
Mode field diameter | 3.6 ± 0.5 um @ 405nm | 3.4 um @ 488nm | 4.2 um @ 630nm | 4.9 um @ 780nm | 6.6 ± 0.7 um @ 980nm |
Numerical aperture | 0.12 | 0.12 | 0.12 | 0.12 | 0.12 |
Return loss | 60 dB Typical | ||||
Fiber optic connector | FC/APC | ||||
Key width | 2.00 ± 0.02 mm | ||||
Alignment method | Narrow Key Aligned to Slow Axis | ||||
Fiber length
| 1.0 +0.075/-0 m for Item NumbersEnding in -1 | ||||
2.0 +0.075/-0 m for Item NumbersEnding in -2 | |||||
5.0 +0.075/-0 m for Item NumbersEnding in -5 | |||||
10.0 +0.075/-0 m for Item NumbersEnding in -10 | |||||
Loose tube type | 900um/2mm/3mm loose tube optional | ||||
Operating temperature | 0 to 70 ℃ | ||||
Storage temperature | -45 to 85 ℃ |
PN# | PM-1064-2-1-FC/APC | PM-1310-2-1-FC/APC | PM-1550-2-1-FC/APC | PM-2000-2-1-FC/APC |
Test wavelength | 1064 nm | 1310 nm | 1550 nm | 2000 nm |
Operating wavelength | 970 - 1550 nm | 1270 - 1625 nm | 1440 - 1625 nm | 1850 - 2200 nm |
Cutoff wavelength | 920 ±50 nm | 1200 ±70 nm | 1370 ±70 nm | 1720 ±80 nm |
Fiber type | PM980-XP(Panda) | PM1300-XP(Panda) | PM1550-XP(Panda) | PM2000(Panda) |
Maximum insertion loss | 0.7 dB | 0.5 dB | 0.5 dB | 0.5 dB |
Minimum extinction ratio | 22 dB | 23 dB | 23 dB | 23 dB |
Mode field diameter | 7.7 um@ 1064 nm | 9.3 ±0.5 um @ 1300 nm | 9.9 ±0.5 um @ 1550 nm | 8.6 um @ 2000 nm |
Numerical aperture | 0.12 | 0.13 | 0.125 | 0.20 |
Return loss | 60 dB Typical | |||
Fiber optic connector | FC/APC | |||
Key width | 2.00 mm ±0.02 | |||
Alignment method | Narrow Key Aligned to Slow Axis | |||
Fiber length | 1.0 +0.075/-0 m for Item NumbersEnding in -1 | |||
2.0 +0.075/-0 m for Item NumbersEnding in -2 | ||||
5.0 +0.075/-0 m for Item NumbersEnding in -5 | ||||
10.0 +0.075/-0 m for Item NumbersEnding in -10 | ||||
Loose tube type | 900um/2mm/3mm loose tube optional | |||
Operating temperature | 0 to 70 ℃ | |||
Storage temperature | -45 to 85℃ |
Note:
a. Measured at the test wavelength.
b. Mode field diameter (MFD) is a nominal value. The diameter at the 1/e² power position in the near field.
c. Numerical aperture (NA) is a nominal value.
1550PM Fiber Optic Patch Cord Experimental Test:
1.End-face inspection
2.IL Test
Laser power before connection
Power after connecting the fiber optic patch cord
Extinction Ratio Testing
Laser Direct Testing