info@idealphotonics.com
search
6362E Spectrometer
A high-speed, high-performance spectrum analyzer with a wide wavelength range based on diffraction grating spectrometry technology. The 1200-2400nm spectrum range not only covers the communication wavelength band, but also covers the SWIR region. It can be applied to optical system testing such as DWDM and optical amplifiers; testing of optical active devices such as LEDs, FP-LDs, DFB-LDs, and optical transceivers; testing of optical passive devices such as optical fibers and fiber gratings, as well as measurement testing of environmental sensing and medical applications.
Product features:1200nm~2400nm wide spectral scanning range、 50pmMin. spectral resolution、 55dB dynamic range、 -70dBmz high sensitivity、 Free space optical input
Application area:Applicable to optical system testing such as DWDM and optical amplifiers、 Optical active device testing such as LED, FP-LD, DFB-LD, optical transceivers、 Optical passive device testing such as optical fiber and fiber Bragg gratings
Unit Price
Please contact customer service for a discounted quote.
Part Number
6362E-V1.0
Lead Time
Please contact customer service for lead time.
Stock
Please contact customer service for stock availability.
Add to Inquiry
Inquire online
General Parameters
Dimensional Drawing

Main Parameters:

Parameters

Specification

Spectral range

1200~2400nm

Scan span

0.5 1200nm(Light source output options 0nm

Wavelength accuracy

±0.05nm( 1520 ~1580nm)、 ±0.10nm( 1580 ~1620nm)、 ±0.50nm(Full wavelength range

Wavelength linearity

±0.01nm( 1520 ~1580nm)

Wavelength repeatability

±0.015nm( 1min)

Wavelength resolution setting

Standard version 0.05、0.1、0.2、0.5、1、2nm

Min. sampling resolution

0.002nm

Number of sampling points

101~50001、AUTO

Power sensitivity setting

NORMAL、MID、HIGH1、HIGH2 and HIGH3

Power sensitivity

-70dBm( 1800-2200nm)、-67dBm( 1500 1800nm 2200-2400nm)、-62 dBm( 1300-1500nm)(Sensitivity HIGH3)

Max. input power

+20dBm(Each channel, full wavelength range)

Max. safe input power

+25dBm(Total input power)

Power accuracy

±1.0dB(1550nm Input Power -20dBm Sensitivity MID HIGH1-3)

Power linearity

±0.05dB(Input Power -30~ +10dBm Sensitivity MID HIGH1-3)

Polarization dependence

±0.1dB(1550nm)

 

Dynamic Range

45dB(Peak±0.4nm Resolution 0.05nm) 55dB(Peak±0.8nm Resolution:0.05nm)   1523nm Sensitivity  HIGH1-3)

Applicable optical fiber

SM(9.5/125μm)、MM(GI  50/125μm、GI 62.5/125μm、Large core diameter Max. 200μ m)

 

Light source output options

Standard calibration light source、

DFB/FP light source (standard 1550nm, other wavelengths optional), SLED light source (band range optional)

Other light source types and accessories can be customized


Note: For devices that do not use the gas absorption cell calibration light source option, wavelength calibration and optical axis alignment can be performed using an external light source.

 

 

Appendix 1: Model and Part Number Comparison Table

Part Number

Stock Number

Title

Spectral Range

Span

Wavelength Accuracy

Wavelength Repeatability

Wavelength Resolution Setting

Min.Sampling resolution

6362E- V1.0


6362E Spectrometer

1200~24 00nm

0.5nm~  1200nm (Full range span),0n

m

±0.05nm(1520-158 0nm),±0.10nm(1 580-1620nm),

±0.50nm(Full range)

±0.015nm (1 Min.)

Standard version:0. 05、0.1、 0.2、0.5、 1、2nm

0.002nm

 

Product Recommendation