PN# | M2691 |
Output Voltage | 0~+150V |
Output Current | ±5mA(AC)max ±5mA(DC)max |
Output Resistance | 220Ω |
Gain | 30x (fixed), within ±1% |
Frequency Characteristics | Above 1kHz (no load, -3dB point) |
Nonlinearity | Below ±0.5% |
Noise | Noise < 1mVrms (under 1μF load) ※1 |
Temperature Drift | ±5mVPC(typical value) |
Input Voltage | 0-+5V |
Signal Input | Non-inverting input (relative to output) |
Input Resistance | 100KΩ |
Input/Output Connectors | 8-pin terminal connection wire: AWG28-16, L = 7mm ± 1mm |
Grounding | Input and output grounds are at the same potential and insulated from the housing. Can be grounded to the housing for input/output. |
Power Supply Voltage | DC +11-+14V |
Operating Environment | Temperature and humidity: 0 ~ +40°C, 85% RH or below, indoor environment close to 1 atmosphere, free from corrosive gases. |
Power Consumption at Rated Output | Approx. 250mA (Power supply: DC+12V) |
No Load Loss | Approx. 150mA (Power supply: DC+12V) |
Instantaneous Current | Approx. 4A for 100μs (Power supply: DC+12V at rated output) |
Dimensions (mm) | 75Wx20Hx50D |
Weight | Approx. 70g |
Accessories | Short rod (for connecting terminal block 7-8) |
AC Adapter (sold separately) | Model: AD-K120P100 (I/P: 100-240V, 50/60Hz, 0.35A; O/P: DC12V, 1A) 2V1A, ) ※This adapter is for this product only; other adapters should not be used. |
During measurement, the 7-8 terminals are connected to the short rod.
Operating Instructions
3-1. Power Supply for the Mini Voltage Driver
The power supply voltage is DC: 11~14V. When powered on, the green LED will light up.
[DC12V +] ・ Connect to the positive voltage
[DC12V -] ・ Connect to OV (ground)
★ When using the dedicated AC adapter (AD-K120P100), the red wire at the front end of the cable is the positive voltage.
3-2. Input Signal
The device can handle an input voltage range of 0~+5V. The GND terminal side is the ground level for single-ended input. For an input signal of +5V, the output voltage will be +150V.
3-3. Output Current
The output current is limited to approximately 5mA by the current limiter. In case of overload, if the temperature of the device rises, the thermal switch (SW) will cut off the output at around 60°C. (The thermal switch will automatically reset when the temperature decreases.)
3-4. Insulation
The external housing of the device, FG (8-pin) and the input/output GND (pins 2, 4, 6, 7) are electrically isolated and not connected. When connecting the box to GND, please use the included short rod between terminals 7-8. (A short rod is pre-connected when shipped.)